+7 (499) 390-91-21 Message to Telegram Our YouTube channel Message to MAX

Voltage inverters

  • Trade mark:Voltag
  • Series:SBPM-IN
  • Warranty:36 months
  • Protection class:IP20-IP54
  • Country of manufacturing:Russia
  • Power: from 5 to 200 kVA

Key advantages

  • Equipment service life of at least 25 years
  • 3-year equipment warranty

Options

  • Convenient control system (active mimic diagram, measurement of key parameters, settings, event log)
  • Parallel operation without an information channel (cable)
  • Galvanic isolation of the load from DC voltage
  • Protection against deep battery discharge
  • Independent control boards for inverter and bypass
  • Unified touch operator panel
  • Power factor (cos φ) = 1
  • Capability to connect unbalanced loads
The main parameters depend on the type of the Inverter
Nominal output power, kVA Design Heat dissipation, not more, W
5
СБПМ-ИН-Т-5-380-УХЛ4
600х600х2100
450
10
СБПМ-ИН-Т-10-380-УХЛ4
600х600х2100
900
15
СБПМ-ИН-Т-15-380-УХЛ4
600х600х2100
1 115
20
СБПМ-ИН-Т-20-380-УХЛ4
600х800х2100
1 807
30
СБПМ-ИН-Т-30-380-УХЛ4
600х800х2100
2 700
40
СБПМ-ИН-Т-40-380-УХЛ4
600х800х2100
3 600
50
СБПМ-ИН-Т-50-380-УХЛ4
600х800х2100
4 500
60
СБПМ-ИН-Т-60-380-УХЛ4
800х800х2100
5 850
80
СБПМ-ИН-Т-80-380-УХЛ4
800х800х2100
7 200
100
СБПМ-ИН-Т-100-380-УХЛ4
1200х800х2100
9 000
120
СБПМ-ИН-Т-120-380-УХЛ4
1600х800х2100
10 800
150
СБПМ-ИН-Т-150-380-УХЛ4
1600х800х2100
13 500
200
СБПМ-ИН-Т-200-380-УХЛ4
2200х800х2100
20 000
Detailed characteristics
Parameter Standart value Optionally
Nominal input voltage, V = 220 / 400 = 110 / 700
Allowed deviations of input voltage, % from nominal value ± 15 ± 20
Bypass line power supply frequency, Hz 50 ± 5 6 / 400
Nominal output voltage, V 3х380 / 3х400 3х220 / 3х230 / 1х220 / 1х230
Output frequency, Hz 50 ± 0,1 50 ± 0,05
Stability of output voltage, % from Unom ±2 ±1
Overload capability, % from Inom Under operation from the grid: up to 110% - 20 min, up to 125% - 10 Under operation from the grid: up to 110% - 20 min, up to 125% - 10 min, up to 150% - 1 min, 200% - 30 sec, 250% - 10 sec
Output voltage regulation range, % from Unom ± 2 ± 1
Cross-factor 3:1 To 7:1
Asymmetric load, % from Inom Up to 100 -
Short circuit, % Inom / msec 300 / 100 700 / 100
Efficiency, not less, % 90 95
Communication interface RS 485, Ethernet RS 232
Communication protocol Modbus RTU, TCP IEC 60870-5-101 / 61850
Availability of "dry" contacts 4 pcs. (configured) 8 pcs.
Indication of equipment operation Sensor LCD panel -
Servicing One-way Two-way
Color RAL 7035 Any RAL
External cables input From bottom From top
Protection degree according to GOST 14254-80 IP 20 Up to IP 54
Earthquake resistance 6 points by scale MSK-64 Up to 9 points by MSK-64 / 20G
Operation temperature From 0 to +40°C From -40 to +45°C
Climatic design УХЛ 4 УХЛ 2 / Т1 — Т3
Battery current sensor Buttery current remote sensor Buttery internal current sensor
Monitoring of insulation resistance - AC / DC relay of monitoring of insulation resistance
Base 100 mm 200 mm
Set of spares for 1 year of operation for 3 years of operation

Manufactured equipment